Thanks, good point. Sending SIBD once without reading first isn't a resend. The result no longer depends on the read being right, and the read is only there to confirm. It also fixes a weak spot in my current code. If port 23 doesn't answer, the sequence trusts the HTTP value, so a stale value can still end up as already in the log. One thing I've seen on my receiver (AVC-X6700H). In standby, SI[code] turns the main zone on but doesn't change the input. So I still need to check the power first. Once the zone is on, I can send SIBD every time. For power, I send ZMON (main zone only), which also sets the state directly. I like your idea of sorting devices by whether their command sets the state or toggles it. It's clearer than the "read first" rule I wrote. Changing the plugin that way is one option, and I'd like to think it over a bit.